F3 Series Charger Manual
13
-
5.1 Troubleshooting Table
If there is a problem an
d you suspect the charger is at fault, turn off the AC mains supply before
proceeding. Ensure that the following are correct: AC input wiring, battery and/or load connections
and PC card connectors. Ensure no foreign objects are in charger.
Charge Fail
failure
board
Check fuse for continuity
board
Voltage" under Symptom
circuit failure
Test all power diodes with
meter, perform SCR test on all
Replace all shorted, open, or
bad parts
excessive output
control board is lit
Shut off AC and DC breakers
for at least 2 minutes, then
trips
or freewheeling
Check all power devices for
shorts
Replace shorted device(s)
or DC
failure
board
board to SENS for repair
voltage / Low
failure
board
Voltage pot (R34)
Adjust pot and see if output
voltage is affected
Adjust R34 to correct output
voltage
Turn off DC breaker, check
voltage on INSIDE breaker
Check load for problems, and
check battery condition
Test all power diodes and
SCRs (figure 5.2)
Check for obstruction of top
and bottom vents
Check for vertical mounting of
charger
Verity that room temperature
is less than 50 C
Verity that AC input voltage
is not higher than charger's
specified operating range
Check for failure of one phase
Contact electrician or utility
company
Disconnect capacitors one at a
time and check for change in
corrected output voltage
Komentarze do niniejszej Instrukcji